1. 91久久精品美女高潮不断,91久久夜色精品国产网站,男按摩师舌头伸进去了电影,国产一区二区三区高清视频,区一区二区三区中文字幕,国产亚洲av片在线观看18女人,国产精品久久久久久无码五月,国产精品久久久香蕉
      熱門搜索: 魚硫酸角質(zhì)素(KS)ELISA試劑盒 白介素6(IL6)ELISA試劑盒(種屬:魚) 魚白介素10(IL10)ELISA試劑盒發(fā)貨及時(shí) 斑馬魚白介素12BELISA試劑盒發(fā)貨及時(shí) 兔載脂蛋白B(apo-B)ELISA試劑盒發(fā)貨及時(shí) 兔孕酮(PROG)ELISA試劑盒發(fā)貨及時(shí) 兔羥脯氨酸(Hyp)ELISA試劑盒發(fā)貨及時(shí) 兔抗酒石酸酸性磷酸酶ELISA試劑盒發(fā)貨及時(shí) 兔晶體蛋白α(Cryα)ELISA試劑盒發(fā)貨及時(shí) 兔結(jié)締組織生長(zhǎng)因子ELISA試劑盒發(fā)貨及時(shí) 兔基質(zhì)金屬蛋白酶9ELISA試劑盒發(fā)貨及時(shí) 兔肺表面活性物質(zhì)相ELISA試劑盒發(fā)貨及時(shí) CD206分子ELISA試劑盒(種屬:小鼠) CC趨化因子受體6ELISA試劑盒(種屬:小鼠) 阻抑素(PHB)ELISA試劑盒(種屬:大鼠) 中性內(nèi)肽酶;腦啡ELISA試劑盒(種屬:大鼠)

      新聞中心/ News Center

      您的位置:首頁(yè)  /  新聞中心  /  Human IDO1 ELISA Kit-上海仁捷生物現(xiàn)貨

      Human IDO1 ELISA Kit-上海仁捷生物現(xiàn)貨

      更新時(shí)間:2017-07-24      瀏覽次數(shù):2141

      Human IDO1 ELISA Kit

      Cat.No. RJ-15030

      For the quantitative in vitro determination of Human indoleamine 2,3-dioxygenase 1 concentrations in

       serum - plasma - tissue homogenates - other biological fluids

       

       

      FOR LABORATORY RESEARCH USE ONLY.

      NOT FOR USE IN DIAGNOSTIC PROCEDURES. 

       

      This package insert must be read in its entirety before using this product.

       

      ELISA

      ENZYME LINKED IMMUNOSORBENT ASSAY


      INTENDED USE AND TEST PRINCIPLE

      This IDO1 ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures. The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of IDO1 in the sample, this IDO1 ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus IDO1 concentration. The concentration of IDO1 in the samples is then determined by comparing the O.D. of the samples to the standard curve.

       

      SAMPLE COLLECTION AND STORAGES

      Serum - Use a serum separator tube and allow samples to clot for two hours at room temperature or overnight at 4℃ before centrifugation for 20 minutes at approximay 1000×g. Assay freshly prepared serum immediay or store samples in aliquot at -20℃ or -80 for later use. Avoid repeated freeze/thaw cycles.

      Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 1000×g at 2-8 within 30 minutes of collection. Remove plasma and assay immediay or store samples in aliquot at -20 or -80 for later use. Avoid repeated freeze/thaw cycles.

      Tissue homogenates - For general information, hemolysis blood may affect the result, so you should rinse the tissues with ice-cold PBS (0.01M, pH=7.4) to remove excess blood thoroughly. Tissue pieces should be weighed and then minced to small pieces which will be homogenized in PBS (the volume depends on the weight of the tissue. 9mL PBS would be appropriate to 1 gram tissue pieces. Some protease inhibitor is recommended to add into the PBS.) with a glass homogenizer on ice. To further break the cells, you can sonicate the suspension with an ultrasonic cell disrupter or subject it to freeze-thaw cycles. The homogenates are then centrifugated for 5minutes at 5000×g to get the supernate.

      Cell culture supernates and other biological fluids - Centrifuge samples for 20 minutes at 1000×g. Remove particulates and assay immediay or store samples in aliquot at -20 or -80 for later use. Avoid repeated freeze/thaw cycles.

      Note:  The samples shoule be centrifugated dequay and no hemolysis or granule was allowed.

       

      MATERIALS REQUIRED BUT NOT SUPPLIED

      1.  37 ℃ incubator

      2.  Standard microplate reader capable of measuring absorbance at 450 nm

      3.  Precision pipettes, disposable pipette tips and Absorbent paper

      4.  Distilled or deionized water

       

      REAGENTS PROVIDED 

      All reagents provided are stored at 2-8°C. Refer to the expiration date on the label.

       

      Name

      96 determinations

      48 determinations

      MICROTITER PLATE

      8*12strips

      8*6strips

      STANDARD(6 vial)

      0.3ml/vial

      0.3ml/vial

      SAMPLE DILUENT

      6.0ml

      3.0ml

      ENZYME CONJUGATE

      10.0ml

      5.0ml

      WASH SOLUTION

      25ml

      15ml

      SUBSTRATE A

      6.0ml

      3.0ml

      SUBSTRATE B

      6.0ml

      3.0ml

      STOP SOLUTION

      6.0ml

      3.0ml

      Closure plate membrane

      2

      2

      User manual

      1

      1

      Sealed bags

      1

      1

      Note:

      1.  Standard concentration was followed by: 24, 12, 6, 3, 1.5, 0.75 IU/mL.

      2.  If samples generate values higher than the highest standard, please dilute the samples with Sample Diluent and repeat the assay.

       

      PRECAUTIONS

      • Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.
      • Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.
      • Do not use kit components beyond their expiration date.
      • Use only deionized or distilled water to dilute reagents.
      • Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.
      • Use fresh disposable pipette tips for each transfer to avoid contamination.
      • Do not mix acid and sodium hypochlorite solutions.
      • Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Rat blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.
      • All samples should be disposed of in a manner that will inactivate viruses.
      • Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.
      • Substrate Solution is easily contaminated. If bluish prior to use, do not use.
      • Substrate B contain 20% acetone, keep this reagent away from sources of heat or flame.
      • Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).

       

      REAGENT PREPARATION AND STORAGE

      Wash Solution (1X) - Dilute 1 volume of Wash solution (20X) with 19 volumes of deionized or distilled water. Wash Solution is stable for 1 month at 2-8°C. 

      微信掃一掃

      郵箱:2450868877@qq.com

      傳真:86-區(qū)號(hào)-傳真號(hào)碼

      地址:上海市楊浦區(qū)鐵嶺路32號(hào)1519-10室

      Copyright © 2026 上海仁捷生物科技有限公司版權(quán)所有   備案號(hào):滬ICP備16052159號(hào)-1   總訪問(wèn)量:355985   技術(shù)支持:化工儀器網(wǎng)

      TEL:17302193538

      掃碼加微信
      主站蜘蛛池模板: 中文人妻AV高清一区二区| 2023国产一线二线三线区别| 精品99在线黑丝袜| 用舌头去添高潮无码av在线观看 | 人人妻人人插视频| 久久综合成人精品亚洲另类欧美| 久久综合免费一区二区三区| 亚洲第一综合天堂另类专| 天天做天天爱天天爽综合区| 久久久久久久久888| 亚洲嫩模一区二区三区| 人人妻人人澡人人爽久久av| 无码人妻αⅤ免费一区二区三区 | 欧洲亚洲日韩性无码专区 | 中文字幕亚洲高清在线一区| 午夜精品一区二区三区免费视频| 99热这里只有精品免费| 国产品无码一区二区三区在线| 国产a在视频线精品视频下载 | 亚洲制服丝袜中文字幕在线| 免费国产自产一区二区三区四区| 亚洲一区二区三区精品网| 人人妻人人做人人爽夜欢视频| 娇妻穿丁字裤公交车被c| 三级三级三级A级全黄| 亚洲综合伊人久久综合| 国产精品第一区亚洲精品| 亚洲精品国产A久久久久久| 女人高潮内射99精品| 99www久久综合久久爱com| 久久久久青草大香综合精品| 在线精品亚洲一区二区绿巨人| 亚洲 欧美 自拍 美腿 卡通 | 制服丝袜国产精品| av中文字幕国产精品| 国产免费人成视频在线观看| 亚洲国产精华液2020| 免费无遮挡毛片中文字幕| 一区二区日韩国产精久久 | 韩国一级毛片中文字幕| 久久无码av一区二区三区电影网 |